Sea Water System Diagnostics C Series Page 8-64 Section 8 - Cooling System - Group 08 Pressure Test Attach a pressure gauge to the outlet side of the sea water pump to check pump outlet pressure. Start the engine and record the sea water outlet pressure from low idle to rated speed at 500 rpm increments. This test can be conducted while the vessel is at dock and not in gear or underway. Refer to Procedure 018-018 for Marine engine specifications. If the sea water pump outlet pressure is within specifications, refer to the Temperature Differential Test in this procedure. If sea water pressure is not present, check the pump for damage. Refer to Procedure 008-057.
If the sea water pump outlet pressure is above the maximum specification test the individual sea water system components for excessive pressure drop as described in the Pressure Differential Test step. Refer to Procedure 018-018 for Marine engine specifications.