C Series Charge-Air Cooler Section 10 - Air Intake System - Group 10 Page 10-11 Remove Wear appropriate eye and face protection when using compressed air. Flying debris and dirt can cause personal injury. WARNING WARNING Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50°C [120°F] before removing the pressure cap. Heated coolant spray or steam can cause personal injury. Coolant is toxic. Keep away from children and pets. If not reused, dispose of in accordance with local environmental regulations. WARNING Drain the coolant. Remove the charge air cooler plumbing and cooler. Refer to original equipment manufacturer (OEM) service manual.
Use compressed air to clean debris from the outside of the charge-air cooler. Clean WARNING When using solvents, acids, or alkaline materials for cleaning, follow the manufacturer's recommendations for use. Wear goggles and protective clothing to reduce the possibility of personal injury. WARNING Some solvents are flammable and toxic. Read the manufacturer's instructions before using. Do not use caustic cleaners to clean the charge air cooler. Damage to the charge air cooler will result. CAUTION Flush the charge-air cooler internally with solvent in the opposite direction of normal airflow.
Shake the charge-air cooler and lightly tap on the end tanks with a rubber mallet to dislodge trapped debris. Continue flushing until all debris or oil is removed (i.e., the water runs clear). NOTE: Make sure that the tubes are in the vertical direction when flushing. If the debris can not be totally removed from the charge- air cooler, the charge-air cooler must be replaced.