Cummins — 3666003

C Series Charge-Air Cooler Section 10 - Air Intake System - Group 10 Page 10-13 Leak Test To reduce the possibility of injury if either plug blows off during the test, secure safety chains on the test plugs to any convenient capscrew on the radiator assembly. This test must not be performed without securely fastened safety chains. WARNING To check the charge-air cooler for cracked tubes or header, remove the inlet and outlet hoses from the cooler. The charge-air cooler does not have to be removed from the chassis. Install a plug or cap over the outlet side of the cooler. Install a pressure gauge and a regulated shop air supply line with a shutoff valve to the inlet side of the cooler.

Apply air pressure to the cooler until the pressure gauge reads a steady 207 kPa [30 psi] of air pressure. Shut off the airflow to the cooler and start a stopwatch at the same time. Record the leakage at 15 seconds. If the pressure drop is 48 kPa [7 psi] or less in 15 seconds, the cooler is operational. If the pressure drop is greater than 48 kPa [7 psi] in 15 seconds, check all connections again. Determine if the pressure drop is caused by a leaky charge-air cooler or a leaky connection. Spray soapy water on all hose connections, and watch for bubbles to appear at the location of the leak. If the pressure drop is caused by a leaky connection, repair the connection and repeat the test.

If the leak is within the charge-air cooler, repeat the test to verify the accuracy of the pressure drop measurement. Similar pressure drop readings must be obtained in at least three consecutive tests before the reading can be considered accurate. NOTE: If a charge-air cooler leaks more than 48 kPa [7 psi] in 15 seconds, it will appear as a major leak in a leak tank.