Air Intake Restriction C Series Page 10-14 Section 10 - Air Intake System - Group 10 If the pressure drop is greater than 48 kPa [7 psi] in 15 seconds, the charge-air cooler must be replaced. Refer to the OEM service manual for replacement instructions. NOTE: Charge-air coolers are not designed to be 100- percent leak free. If the pressure drop is less than 48 kPa [7 psi] in 15 seconds, then the charge-air cooler does not need to be replaced. Temperature Differential Test Install a temperature gauge in the intake manifold. Lock the fan drive in the ON mode to prevent erratic test results. This can be done by installing a jumper across the temperature switch or supplying shop air to the fan.

Refer to the OEM service manual for the lockup procedure. NOTE: Some applications have a manual switch that will lock the fan on. Operate the engine at rated rpm and load. Record the intake manifold temperature. Measure the ambient temperature at least 2 feet in front of the vehicle. The maximum temperature differential must not be greater than 25°C [77°F]. If the temperature differential is greater than 25°C [77°F], check the charge-air cooler for dirt and debris on the fins, and clean as necessary. If the problem still exists, check the cooler for internal contamination or plugging. Air Intake Restriction (010-031) Measure NOTE:

For naturally aspirated engines, measure the intake restriction just before the intake manifold. Install a vacuum gauge or water manometer, Part Number ST-1111-3, in the intake air piping. The gauge adapter must be installed at a 90-degree angle to the airflow in a straight section of pipe, one pipe diameter before the turbocharger.