Turbocharger Wastegate Actuator C Series Page 10-26 Section 10 - Air Intake System - Group 10 Install Maintain a minimum distance of 10 mm [0.39 in] between the oil supply line and the turbine housing or exhaust manifold, and 5 mm [0.20 in] between the oil supply line and other components to prevent oil line high temperature damage and chafing. CAUTION Apply a thin film of oil to the o-ring seals. Fill the turbocharger oil inlet with clean oil. Install the oil supply line at both the filter head and the turbo bearing housing. Tighten the oil supply line to final torque. Torque Value:
24 N•m [ 212 in-lb ] Turbocharger Radial Bearing Clearance (010-047) Measure Measure the radial clearance of the shaft. Turbocharger Radial Clearance (B) mm in 0.30 MIN 0.012 0.46 MAX 0.018 The turbocharger must be removed for replaced if the clearances are out of specification. Refer to Procedure 010-033. Turbocharger Wastegate Actuator (010-050) Remove NOTE: Prior to removal, note the position of the control rod from the boost capsule housing and orientation of the boost capsule hose connector in relation to the mounting bracket.