C Series Intake Manifold Air Heater Wiring Harness Section 10 - Air Intake System - Group 10 Page 10-31 Intake Manifold Air Heater Wiring Harness (010-122) Initial Check Remove and check the fuse in the power circuit to the heater control module. With the keyswitch in the ON position, verify the voltage from the keyswitch circuit to the fuse. If no or low voltage is indicated, the wiring and connections from the keyswitch to the fuse holder must be checked. The air heater will not function properly unless the specified voltage is obtained. Voltage Check Connect the positive lead of the multimeter to the air heater element terminals. Ground the negative lead to a good known ground.
Voltage System VDC 12-VDC 10.5 to 17 24-VDC 22 to 29