Cummins — 3666003

Intake Manifold Air Heater Wiring Harness C Series Page 10-32 Section 10 - Air Intake System - Group 10 Heater grids and studs can get hot enough to burn skin. WARNING Do not recycle the keyswitch repeatedly in a short period of time. This may cause damage to the grids or the wiring. CAUTION Attach a multimeter to the heater element wires. Clamp the multimeter current probe around both wires to the air heater. The following test will only last up to 20 seconds. Refer to the preheat cycle time in the General Information section. Turn the keyswitch to the ON position. Do not crank the engine. Record both the voltage and amperage readings.

The keyswitch must be turned OFF and ON again in order to recycle. Voltage and amperage readings must be within the specified limits. If no voltage is detected, disconnect the intake temperature sensor. Disconnecting the intake temperature sensor simulates intake manifold temperature of less than 0°C [32°F]. This overrides the temperature circuit if the intake manifold temperature is too hot to allow the heater to turn on. Turn the keyswitch OFF, then ON again. Recheck the voltage and ampere readings. Refer to Section E for the sensor location. Verify the preheat cycle. After 20 seconds the voltage and amperage should drop to zero when the cycle ends.

The WAIT TO START lamp, if equipped, will stay on for 20 seconds. After 20 seconds, the lamp will begin to flash indicating the heater cycle has turned off. The lamp will continue to flash as long as the intake temperature sensor is disconnected indicating an open circuit. System Voltage Voltage Range Amperage Range 12 10.5 to 17 80 to 110 (1 grid) 12 10.5 to 17 160 to 220 (2 grids) 24 22 to 29 80 to 110