C Series Intake Manifold Air Heater Wiring Harness Section 10 - Air Intake System - Group 10 Page 10-33 If no voltage is detected at the heater grid with the intake temperature sensor disconnected, check the voltage to the solenoid. Connect the multimeter and check the supply voltage to the solenoid secondary circuit (large terminal). If no voltage is present, repair the wiring to the solenoid. Refer to Procedure 010-126, Intake Manifold Air Heater Solenoid Switch. If voltage is present, check the solenoid. Check the voltage on the primary side of the solenoid, small terminal to small terminal. If no voltage is present, check the ground.
If voltage is present at both terminals, replace the solenoid. Check the voltage from the solenoid positive primary circuit to a good known ground. If no voltage is present, check the voltage to the heater control module. If voltage is present, restore the ground to the solenoid. The solenoid and heater control module share the same ground. Check the wire or clean the connectors.