C Series Intake Manifold Air Heater Control Module Section 10 - Air Intake System - Group 10 Page 10-39 If there is no voltage to the heater control module, check the system voltage. Refer to Procedure 010-122. The air heater will preheat as long as the intake manifold temperature is below 35°C [95°F]. This will repeat each time the keyswitch is turned from the OFF to the ON position. The multimeter and ammeter should indicate the cycle for proper voltage and amperage. Refer to the Intake Manifold Air Heater System General Information in Section F to verify the proper cycle. If no voltage was detected, disconnect the intake temperature sensor.
Disconnecting the intake temperature sensor simulates an intake manifold temperature of less than 0°C [32°F]. This overrides the temperature circuit if the intake manifold temperature is too hot to allow the heater to turn on. Turn the keyswitch OFF, then ON again. Recheck the voltage and ampere readings. Refer to Section E for the sensor location. If no voltage and no amperage are detected, check the following: Intake air heater solenoid switch, refer to Procedure 010-126 Intake manifold air heater element, refer to Procedure 010-124. If all systems check out properly and the preheat does not cycle according to the heater cycle chart, replace the heater control module.
System Voltage Voltage Range Amperage Range 12 10.5 to 17 80 to 110 (1 grid) 12 10.5 to 17 160 to 220 (2 grids) 24 22 to 29 80 to 110