Cummins — 3666003

Air Compressor Carbon Buildup C Series Page 12-2 Section 12 - Compressed Air System - Group 12 If the total carbon deposit exceeds specification, inspect the air discharge line connections, up to the first tank or until the carbon deposit is less than 1.6 mm [0.063 in]. Clean or replace the lines or connections that exceed this specification. WARNING The air discharge line must be capable of withstanding extreme heat and pressure to prevent personal injury and property damage. Refer to the OEM's specifications. NOTE: If the total carbon deposit thickness exceeds specification: Remove and clean or replace the air discharge line. Refer to manufacturer's material specifications.

Remove the air compressor from engine; refer to Procedure 012-014. Inspect the underloader components; refer to the Air Compressor Shop Manual, Bulletin 3810242, for detailed instructions on servicing the unloader components. The air discharge line must be capable of withstanding extreme heat and pressure to prevent personal injury and property damage. Refer to the OEM's specifications. WARNING Continue to inspect for carbon buildup in the air discharge line connections up to the first or wet tank. Clean or replace any lines and fittings with carbon deposits greater than 1.6 mm [0.063 in]. Refer to the OEM's specifications for cleaning or replacement instructions.