C Series Starter Solenoid Section 13 - Electrical Equipment - Group 13 Page 13-9 If the starting motor solenoid does not make an audible sound, check for loose wiring connections. Use a digital multimeter, Cummins Part Number 3164488, or equivalent, to set the voltage scale. Check for system voltage at the starting motor solenoid battery terminal. If the multimeter indicates system voltage at the starting motor battery terminal, check the voltage at the starting motor solenoid S terminal, when the starting switch is energized.
If the multimeter indicates system voltage at the S terminal, but the starter does not engage, the starting motor solenoid is malfunctioning and the starter must be replaced. Refer to Procedure 013-020. If the multimeter does not indicate system voltage at the S terminal, check: Fuses Voltage to the ignition switch and magnetic switch. Refer to "Starting Motor Switch and Magnetic Switch - Checking" in this section. Refer to Procedures 013-017 and 013-018 Application safety shutoff systems