Cummins — 3666003

C Series Crankcase Blowby, Measure Section 14 - Engine Testing - Group 14 Page 14-19 The following charts show the relationship of measured pressure to flow rate, depending on the blowby tool used.

Blowby Conversion Table (5.61-mm [0.221-in] orifice, Blowby Tool, Part Number 3822476) mm [in] of H O 2 Liter [cfm] per Minute 25.4 [1] 27 [0.953] 50.8 [2] 40 [1.413] 76.2 [3] 48 [1.695] 101.6 [4] 58 [2.048] 127 [5] 64 [2.260] 152.4 [6] 71 [2.507] 177.8 [7] 76 [2.684] 203.2 [8] 81 [2.860] 228.6 [9] 86 [3.037] 254 [10] 90 [3.178] 279.4 [11] 94 [3.320] 304.8 [12] 98 [3.461] 330.2 [13] 102 [3.602] 355.6 [14] 105 [3.708] 381 [15] 109 [3.849] 406.4 [16] 112 [3.955] 431.8 [17] 115 [4.061] 457.2 [18] 118 [4.167] 482.6 [19] 121 [4.723] 508 [20] 124 [4.379] 533.4 [21] 128 [4.520] 558.2 [22] 131 [4.626] 584.2 [23] 135 [4.767] 609.6 [24] 137 [4.838] 635 [25] 140 [4.944] 660.4 [26] 144 [5.085] 685.8 [27] 147 [5.191] 711.2 [28] 150 [5.297] 736.6 [29] 154 [5.438] 762 [30] 157 [5.544] 787.4 [31] 160 [5.650] 812.8 [32] 163 [5.756] 838.2 [33] 166 [5.862] 863.6 [34] 169 [5.968] 889 [35] 172 [6.074] Blowby Conversion Table (7.67-mm [0.302-in] orifice, Blowby Tool, Part Number 3822566) mm [in] of H O 2 Liter [cfm] per Minute 25.4 [1] 50 [1.766] 50.8 [2] 84 [2.966] 76.2 [3] 103 [3.637] 101.6 [4] 119 [4.202] 127 [5] 133 [4.697] 152.4 [6] 145 [5.121] 177.8 [7] 155 [5.474] 203.2 [8] 164 [5.792]