C Series Flywheel Housing, REPTO Section 16 - Mounting Adaptations - Group 16 Page 16-35 When the idler shaft has been seated, remove the capscrew. Apply pipe sealant, Part Number 3375066, to the threads of the idler shaft capscrew. Apply Lubriplate™ 105 under the head of the capscrew and tighten to it's final torque value. Torque Value: 105 N•m [ 75 ft-lb ] Apply a film of cup plug sealant, Part Number 3375068, to the outside diameter of the cup plugs. Use a driver, Part Number 3823710, to install the cup plugs into the housing as shown. NOTE: When installing cup plugs, make sure they are flush with the spot face on the flywheel housing and are not crooked.

Coat the flywheel housing drain plug with pipe sealant and install in the hole in the bottom of the flywheel housing. Tighten the plug. Refer to the pipe plug torque values in section 017 for different plug sizes. Turn the output flange so that the flat sides are on the top and bottom. This prevents any interference when the transmission is installed onto the housing.