Fendt 900 Vario COM III — 6 B085 camshaft speed

2000 - Overall system/engine A - General I001547 Fig. 7. Measurement of inductive sensors The inductive sensor receives pulses directly from a pulse generator (gearwheel or disc). Where the magnetic field of the inductive sensor is intersected by measuring points, an AC induction voltage (VAC) is generated. The A051 - ECU, engine control unit (EDC 7). calculates the speed from the number of voltage pulses (frequency). I005238 Fig. 8. I001550 Fig. 9. 19 T002543 Version 2 05-10-2009 The amplitude of the pulse is proportional to the speed (i.e., the voltage increases as the speed increases).

Calculation of crankshaft revs (engine speed) on the basis of the oscilloscope display The A051 ECU, engine control unit calculates the speed from the number of voltage peaks. Clearance between sensor and camshaft gear: 1.0 to 2.0 mm 919 .. 0101-1000 925 .. 1001- 934 .. 0101-1000 919 .. 1001- 928 .. 0101-1000 934 .. 1001- 922 .. 0101-1000 928 .. 1001- 922 .. 1001- 931 .. 0101-1000 925 .. 0101-1000 931 .. 1001- A Reference mark (cylinder 1 ignition) NW Camshaft gear delta t Time between voltage peaks Induction voltage and frequency IN Inductive sensor Ua Induced voltage N OTE : see §77 A - General