B3.9, B4.5, B5.9 Industrial Fuel Filter (Canister Type) Section 5 - Maintenance Procedures at 500 Hours or 6 Months Page 5-3 Open the bleed screw. Operate the hand lever until the fuel flowing from the fitting is free of air. Tighten the bleed screw. Torque Value: 9 N•m [ 80 in-lb ] Air and fuel can be vented from the illustrated vent locations on the Bosch® VE fuel injection pumps. Loosen the vent screw and operate the priming lever on the fuel transfer pump until the fuel injection pump is primed. Tighten the vent screw. Torque Value: 9 N•m [ 80 in-lb ] It is necessary to turn the keyswitch to the ON position. Because the engine can start, be sure to follow all safety precautions.
Use the normal engine starting procedure. CAUTION CAUTION When using the starting motor to vent the system, do not engage it for more than 30 seconds, or starter damage will occur. Wait 2 minutes before starting the engine again. Air can also be vented through the fuel drain manifold line by operating the starting motor.