Komatsu — CHANGE OIL IN HYDRAULIC TANK, REPLACE HYDRAULIC OIL FILTER ELEMENT, CLEAN HYDRAULIC TANK STRAINER

. MAINTENANCE SERVICE PROCEDURE CHANGE OIL IN HYDRAULIC TANK, REPLACE HYDRAULIC OIL FILTER ELEMENT, CLEAN HYDRAULIC TANK STRAINER WARNING carefully. remove cap. 4 - 63 EVERY 2000 HOU Maintenance for every 250, 500 and 1000 hours service s hould be carried out at the same t The immediately temperature to go dow n before starting the work. When removing the oil filler cap, oil may spur t out, s o pus h the cap down t o release the internal press ure, then remove the cap Refill capacity: 71 lit ers (18.76 US gal) 1. 2. 3. 1. Lower the work eq uipment to the ground, the n stop the engine. 2. Push down cap of oil filler (F) to releas e the a ir and remove the internal pressure.

Keep cap pushed down, turn it slowly counterclockwise, then 4. of the drain valve (2). Aft er draining the oil, ti ghten drain plug (1) and drain valve (2). Wh en loosening drain valve (1), b e careful not to get oil on yourse 5. Remove bolts (3), element. then remove cover (4) and take out the 6. Clean the inside of case and removed parts and i nsta ll a new element.