Peripheral Devices 17.3.3 Discrete Input/Output Module Installation The discrete I/O module can be mounted in relatively high shock or vibration environments. The module can also tolerate moist environments and operate accurately in ambient temperatures ranging from -40°C to 85°C. The module can also be remotely mounted at a distance usually limited by the CAN data link requirements. The nominal power supply voltages are 12V and 24V. The maximum current draw is 400 mA plus 50 mA for each energized relay when the module is powered at 12V. Connection should be to a clean source, preferably to the same source as the engine ECU.

Do not access power and ground for the module from the starter terminals. Refer to Figure 3 for the power and CAN data link connector pinout. The Caterpillar part number for the mating connector and wedge assembly is 155-2265. For the CAN data link wiring requirements refer to Section 5.4. Figure 3 The module has a ground stud that should be used to ground the case. The 12 discrete inputs are switch to ground inputs with internal pull-up resistors. The module will determine an input as being LOW when the voltage at the input is 0 to 0.8V. The module will determine an input as being HIGH when the voltage at the input is 3.75V to 24V.

Figure 4 is a representation of one of the 12 discrete inputs. Figure 4 A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 121