OPERATION Using Automatic Reverse Rotation Function The fan automatically switches from normal rotation to reverse rotation and from reverse rotation to normal rotation according to the programmed time intervals. This allows the wheel loader to have the optimum heat balance (cooling). The automatic reverse mode is factory-programmed with a default time interval. When activated, the fan reverses every two SMR (service meter reading) hours for two minutes. The ability to modify both the reverse time interval and the amount of time the fan rotates in reverse is described in the Shop Manual . Reversing interval information:
The heat balance (cooling) of the wheel loader is extremely important to ensure that the machine operates to its maximum ability within the design criteria. To make sure this is possible, the hydraulic-driven cooling fan has an operating temperature range that it must work in. If the wheel loader is outside of these parameters then the reversing fan function (both manual and automatic reverse) will not occur until the wheel loader gets within these parameters. If the reversing happens when the machine is at low idle, it will not automatically spin at full speed in the reverse direction. To spin at full speed, the operator must take the machine to high idle.
Switching from Normal Rotation to Reverse Rotation The fan will switch from normal rotation to reverse rotation only if all the following conditions are fulfilled. If all the conditions are not fulfilled, the fan direction will not change. Conditions: The cooling fan automatic reverse rotation switch is at position (a). The engine water temperature is less than 90°C (194°F). (The indicator on the engine water temperature gauge is below horizontal.) The hydraulic oil temperature is less than 90°C (194°F). (The indicator on the hydraulic oil temperature gauge is below horizontal.) The torque converter oil temperature is below 100°C (212°F).
(The indicator on the torque converter oil temperature gauge is below horizontal.) The set time for switching has passed. At least 30 seconds have passed since the engine was started. If the direction is switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change from flashing and will stay illuminated. If the direction is not switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change from OFF to flashing and will continue to flash. 2-56 WA430-6 Fan Reverse Interval Reverse Rotation Time Factory Setting 2 hr 2 min Adjustment Range 0.1 hr to 200 hr 0.5 min to 10 min