MAINTENANCE When Required Clean, Replace Air Cleaner Element Always stop the engine before doing this procedure. If inspection, cleaning, or maintenance is carried out with the engine running, dirt will get into the engine and damage it. When using compressed air, there is danger that dirt may be blown around and cause serious injury. Always use protective glasses, dust mask, and other protective equipment. Inspect Air Cleaner Element The air cleaner clogging caution lamp on the machine monitor lights up when the air cleaner element is clogged. For more information about this warning lamp, see “Air Cleaner Clogging Caution Lamp” on page 2-23.
If you wish to check the state of the air cleaner element, there is a dust indicator (1) installed inside the engine hood on the right side of the machine. When the yellow piston of the dust indicator enters the red range (7.5 kPa [1.09 psi]), it is time to clean the air cleaner element. Follow the inspection procedure as described in “Check Air Cleaner” on page 2-86. Clean Outer Element 1. Stop the engine. 2. Open the engine side cover on the right side of the chassis. 3. Remove three clips (1), then remove cover (2). Remark Do not remove the inner element (4). If it is removed, dust will enter and cause engine trouble.
The inner element is removed ONLY when you are replacing the outer element; see “Replace Element” on page 3-30. 4. Remove the outer element (3) from the air cleaner. 3-28 WA430-6