Komatsu — Clean Element in Air Conditioner Fresh Air Filter

MAINTENANCE Clean Element in Air Conditioner Fresh Air Filter If compressed air is used, there is danger that dirt may fly and cause personal injury. Always wear safety glasses, dust mask, and other protective equipment. Remark If the air conditioner has been used, the air filter should be cleaned. If the filter is clogged, the air flow will be reduced; there will be an abnormal noise from the air conditioner unit. Articulate the machine completely to the right before cleaning the air conditioner. 1. Stop the engine. 2. Stop the air conditioner. 3. Insert the starting key into key slot (1), release the lock; loosen knob (2); and open cover (3). 4. Take out element (4) and clean it. 5.

Direct dry compressed air (less than 7.4 kg/cm 2 [100 psi]) to the element from inside along its folds, then direct it from outside along its folds and again from inside. 6. Replace the filter with a new part if the clogging cannot be removed with compressed air, or if it has been used for one year. 7. After cleaning, return filter (4) to its original position and close the cover. 8. Use the starting switch key to lock the cover. Do not forget to remove the starting switch key. 3-60 WA430-6