Komatsu — Check Battery Electrolyte Level

Every 250 Hours Service MAINTENANCE Maintenance for every 50 and 100 hours service should be performed at the same time. Check Battery Electrolyte Level Perform this check before operating the machine. See additional information about handling a battery safely in “Battery Information” on page 1-45. Do not use the battery if the battery electrolyte level is below the LOWER LEVEL line. This situation will accelerate deterioration of the inside of the battery and reduce the service life of the battery. In addition, it may cause an explosion. The battery generates flammable gas and there is danger of explosion. Do not bring fire or sparks near the battery. Battery electrolyte is dangerous.

If it gets in your eyes or on your skin, wash it off with a large amount of water and consult a doctor immediately. When adding distilled water to the battery, do not allow the battery electrolyte to go above the UPPER LEVEL line. If the electrolyte level is too high, it may leak and cause damage to the paint surface or corrode other parts. Remark If there is a danger that the battery water may freeze after refilling it with purified water (e.g., commercially available replenishment water for a battery). Add the water only the next day before starting work. Try to check the electrolyte level on a daily basis. Be sure to check it at least once a month.

Follow the basic safety procedures provided here. When Checking Electrolyte Level from Side of Battery If it is possible to check the electrolyte level from the side of the battery, do this procedure. 1. Open the cover of the battery box. There are two battery boxes, one on each side at the rear of the machine. 2. Use a wet cloth to clean the area around the electrolyte level lines and check that the electrolyte level is between the UPPER LEVEL (U.L) and LOWER LEVEL (L.L) lines. If you wipe the battery with a dry cloth, static electricity may cause a fire or explosion. 3.

If the electrolyte level is below the midway point between the UPPER LEVEL (U.L) and LOWER LEVEL (L.L) lines, remove cap (1) and add distilled water to the U.L line. If distilled water has been added to any cell of cap (1), add distilled water also to the other cells. 4. Clean the vents of the battery caps, then close the caps securely. Keep the top of the battery clean and wipe it with a wet cloth. Remark If distilled water is added above the UPPER LEVEL (U.L.) line, use a syringe to lower the level to the UPPER LEVEL (U.L.) line.

Neutralize the fluid that is removed with baking soda (sodium bicarbonate) and then flush it away with a large amount of water, or consult your Komatsu distributor or battery manufacturer. WA430-6 3-61