MAINTENANCE When It Is Impossible to Check Electrolyte Level from Side of Battery If it is impossible to check the electrolyte level from the side of the battery or there is no display of the UPPER LEVEL line on the side of the battery, use this procedure to check the level. 1. Open the cover of the battery box. There are two battery boxes, one on each side at the rear of the machine. 2. Remove cap (1) on the top of the battery; look through the water filler port (2); and check the electrolyte level. If the electrolyte does not reach the sleeve (3), add distilled water so that the level reaches the bottom of the sleeve (UPPER LEVEL line). (A):
Suitable level Electrolyte level is up to bottom of sleeve; surface tension causes electrolyte surface to bulge and poles appear bent. (B): Low Electrolyte level is not up to bottom of sleeve; poles appear straight and not bent. 3. If distilled water has been added to any cell of cap (1), add distilled water also to the other cells. 4. Replace the cap (1) and tighten it securely. Remark If water is added above the bottom tip of the sleeve, use a syringe to remove the electrolyte and lower the level to the UPPER LEVEL (U.L.) line.
Neutralize the removed fluid with baking soda (sodium bicarbonate) and then flush it away with a large amount of water, or consult your Komatsu distributor or battery manufacturer. When It Is Possible to Use Indicator to Check Electrolyte Level If it is possible to use an indicator to check the electrolyte level, follow the instructions provided with the indicator. Check Parking Brake 1. Stop the machine on a dry, downhill slope. 2. Set the parking brake switch to the ON position (A) and check if the parking brake holds the machine in position. Position (A): ON Parking brake is actuated and parking brake pilot lamp illuminates. Position (B): OFF The parking brake is released. 3.
If any problem is found, contact your Komatsu distributor. 3-62 WA430-6