. ATTACHMENTS AND OPTIONS MACHINE READY FOR ATTACHMENT Accumulator WARNING the operation. carried out. 6 - 7 The accum ulator is charged with h igh-pressure nitroge n gas, so mistaken operation may cause an ex plosion, which will lead to serious inj ury or damage. When h andling the accumula tor, alway s do as f ollows. The pre ssure in the hydraulic c ircuit cannot be com pletely re moved. W hen removing the hydraulic equipment, do not stand irection that the oil spur ts out when carrying out the op eration.
In addition, loosen the bolts slowly when carrying out Do not disassemble the accum Do not bring it near flame or di Do not make holes in it or weld Do not hit it, roll it, or subject it When d isposing of the accum ulator, the gas must be release d. Please contact your Komatsu dis tributor to have this work These ac cumulators (6) and ( 7) are installed to reduce t he peak pressure in the hydraulic circu it when the breaker is being used. Normally, do not touch them. NOTICE On machin es equipped with a brea ker, it is necessary to install an accumulator to the breaker piping to match the model number of the brea ker manufacturer.
If n o accumulator is inst alled and the break er is operated, the service l ife of the machine will be reduced. For questions about the breaker, please cont act your K omatsu d istributor. For details , see "CHECK NITROG EN GAS CHARGE PR ESSURE IN ACCUMULATOR (for breaker) (PA GE 4-71)" or "CHECKING CHARGE P RESSURE OF NITROG EN GAS IN ACCUMULATOR (FO R CONTROL CIRCUIT) (PAGE 4-74)".