Komatsu — HYDRAULIC CIRCUIT

. ATTACHMENTS AND OPTIONS MACHINE READY FOR ATTACHMENT Adjusting Oil Flow Depending on the attachment, it is necessary to change the oil flow in the service circuit. For details of setting the oil flow, see "ATTACHMENT OPERATIONS (PAGE 6-19)". Switching Between Breaker and General Attachment When optional attachment is installed and working mode is set to B mode (1) Forms breaker circuit (one-way circuit). (2) Hydraulic oil flowing through breaker circuit passes through additional filter for breaker. (3) Relief valve is set to low pressure. When shipped from factory: 20.6 MPa (210 kgf/cm 2 , 2980 PSI) (4) Maximum oil flow can be adjusted in user mode.

When optional attachment is installed and working mode is set to ATT mode (1) Forms crusher circuit (double-acting circuit). (2) Hydraulic oil flowing through crusher circuit does not pass through additional filter for breaker. (3) Relief valve is set to high pressure. When shipped from factory: 27.4 MPa (280 kgf/cm 2 , 3980 PSI) (4) Maximum oil flow can be adjusted in user mode. 6 - 8 HYDRAULIC CIRCUIT NOTICE The return c ircuit when a b reake r is installed m ust r eturn di rectly to the return filte r, so do not use it except i n B mode. The standar d set p ressure for th e safety valve i n the service valve is set when the machine is shippe d from th e factory.

When B mode is s elected , it is se t to 20.6 MPa (210 k gf/cm 2, 2980 P SI); when ATT mode i s selected, it is se t to 27.4 MPa (280 kgf/cm 3980 PSI). Depending on the attachment, adjustment may be necessary . I n such a case , please ask your Komats u distributor to carry out the adj ustment Switching Hydraulic Circuit Depending on th e type of attachment, set the workin g mode on the monit or as The se t pressure of the s afety valve in t he service valv e and the hydraulic ci rcuit switch is a ccording to t he working mode selected.

Attachment Working mode Hydraulic circuit Set pressure of safety valve in service valve One-way circuit attachment, such as breaker B mode Automatically forms circuit where return circuit does not pass through control valve When shipped from factory: 20.6 MPa (210 kgf/cm2, 2980 PSI) Double-acting circuit attachment, such as crusher ATT mode Automatically forms circuit where return circuit passes through control valve When shipped from factory: 27.4 MPa (280 kgf/cm2, 3980 PSI)