Terex TL160 — 7.8.5 Fuel system

Care and Maintenance 7 7.8.5 Fuel system 7.8.5.1 Checking the fuel level Check the fuel level using the fuel gauge (48/27). Danger of injury due to excessive pressure while refueling. When topping up fuel using the electric refueling pump, open the fuel tank cap to avoid excessive pressure in the fuel tank! Top up fuel every day after use to prevent condensation from forming before the machine is next put into operation. 7.8.5.2 Draining the water separator Fig. 48 Checking the fuel level Machine damage due to full water separator. Never allow the engine to run if the water separator is filled by more than 50%. Failure to do so will result in damage to the engine.

Check daily using the sight glass (49/1) and drain if required. Open the drain (49/2) and collect any escaping water in a suitable container. Dispose of the water according to regulations. Close again the drain (49/2). Fig. 49 Draining the water separator 81/112 TL160 Operating Manual 12.9.08 Version 1.0