Cummins — 4021531

QSB4.5 and QSB6.7 Cooling System Section 5 - Maintenance Procedures at 500 Hours or 6 Months Page 5-7 Shut the engine OFF, allow the cooling system to cool to 50°C [122°F]. Drain the cooling system. NOTE: If the water being drained is still dirty, the system must be flushed again until the water is clean. Fill CAUTION The system must be filled properly to prevent air locks or serious engine damage can result. During filling, air must be vented from the engine coolant passages. Wait 2 to 3 minutes to allow air to be vented; then add mixture to bring the level to the top. Make sure air is vented during the fill process:

The thermostat has check balls that allow air to vent through the thermostat when the thermostat is closed. An air vent port connection, which connects to the top tank/coolant recovery tank of the cooling system, is located next to the water outlet. The system has a designed fill rate of 19 liters [5 gal] per minute. CAUTION Never use water alone for coolant. Damage from corrosion can be the result of using water alone for coolant. Use a mixture of 50-percent water and 50-percent ethylene glycol or propylene glycol antifreeze to fill the cooling system. Verify the coolant recommendations and specifications. Refer to Procedure 018-004 in Section V.