24. SERVICE PROCEDURE 1. Stop the engine and tighten corrosion resistor valve 1 . 2. Raise the lever of radiator cap 2 to release the pressure, then remove the cap. 3. Prepare a container to catch the coolant, then open drain valves 3 and 4 of the radiator to drain the coolant. 4. After draining the water, close drain valves 3 and 4 and fill with city water. 5. When the radiator is full, start the engine, and run it at low idle. Keep the engine running at low idle for 10 minutes until the coolant temperature reaches more than 90°C (194°F). 6. Stop the engine, open drain valves 3 and 4 to drain the water. 7. After draining the water, clean the cooling system with cleaning agent.
For the cleaning method, see the instructions for the cleaning agent. 8. Close drain valves 3 and 4 . 3-26