2011 Drive system W 02-09-07 W 02-09-07 Check piston Tools - Commercial tools Micrometer gauge Internal measuring device References - W 02-09-03 - Special tools 100 400 - Meter Note If the wear limit is reached, the piston has to be changed. Check the piston bolt bore 6 z Remove piston from con rod. О Job card W 02-09-03 . Prepare internal measuring device z Mount probe bolt for the appropriate measuring range in the internal measuring device. z Mount meter with approx. 1 mm pre-tension in the internal measuring device. z Set micrometer gauge to - 26 mm in FL/M engines - 30 mm in BFL/M engines.
z Balance the internal measuring device between the test surfaces of the micrometer gauge and set the meter to the reversal point of the pointer to ”0”. © 11/2004 0312 1571 - 0138 1/4 © 39054 0 © 39054 0 © 34768 1 © 34768 1