Deutz — Deutz 2011 Workshop Manual Level 3

Fuel system W 07-07-05 2011 Testing the opening pressure z Press down the lever of the nozzle tester slowly, with connected pressure gauge. The pressure at which the pointer stands still or suddenly drops is the opening pressure. 07 52 6 Note - When the hand lever of the nozzle tester has been actuated three or four times, the pressure in the spring space has built back up. - The nozzle clamping nut must be loosened again and re-tightened. - The test must be repeated. - If the measured values of three tests are identical, these can be considered valid. 07002 z Remove the injection valve from the nozzle tester.

Setting the opening pressure on the injection valve z Insert the injection valve in the holder, unscrew the nozzle clamping nut and remove all parts. 0312 1600 - 0138 2/6 © 11/2004 © 36293 1 © 36293 1 © 36293 1 © 36293 1 © 36270 1 © 36270 1