MAINTENANCE C. TRAVEL MOTORS REDUCTION OIL (FOR SK210 (LC) -VI) Inspect oil level of travel motor reduction unit on a new machine after the first 50 hours of en- gine operation. Then check every 120 hours. 1. Move machine to a firm, level surface. Operate travel until “DRAIN” plug is positioned at 6:00 o’clock. “FILL/LEVEL” plug should be on the top left side at about 10:00 o’clock. See Figure 4.37A. 2. Stop engine and remove the travel motor re- duction unit oil level plug. See Figure 4.37A. If oil just seeps from the port, oil level is correct. 3. To add oil, remove the oil fill plug and the level plug.
Add extreme pressure gear oil #90 grade GL-4 through the fill orifice until oil just begins to flow out from the level orifice. 4. Use teflon tape on plugs for better sealing. In- stall plugs and tighten securely. NOTE Capacity of each travel motor reduction unit is 4.7 liters (1.2 Gallons). FILL / LEVEL PLUG CAUTION Reduction unit may be under pressure. Remove plug slowly. 4 3. To add oil, remove the oil FILL plug and add Extreme Pressure Gear Oil #90 Grade GL-4 until oil just begins to flow out from the orifice. 4. Use teflon tape on the plug for better sealing. Install plug and tighten securely.
SK210(LC)–VI DRAIN PLUG FIGURE 4.37A NOTE Capacity of each travel motor reduction unit is 5.5 liters (1.5 Gallons). FILL PLUG LEVEL PLUG D. TRAVEL MOTORS REDUCTION OIL (FOR SK250LC-VI & SK250NLC-VI) Inspect oil level of travel motor reduction unit on a new machine after the first 50 hours of en- gine operation. Then check every 120 hours. 1. Move machine to a firm, level surface. Operate travel until “FILL” plug is positioned at 12:00 o’clock, “LEVEL” plug at 3:00 o’clock, and drain plug at 6:00 o’clock on travel motors. See Fig- ure 4.37B. 2. Stop engine and remove the travel motor re- duction unit oil level plug. See Figure 4.37B. If oil just seeps from level port, oil level is correct.
SK250(LC)–VI DRAIN PLUG FIGURE 4.37B CAUTION Clean up all spilled oil. Dispose of all hazardous waste in accordance with government environmental regula- tions. CAUTION Reduction unit may be under pressure. Remove plug slowly. NOTE To replace oil in travel motors, please refer to 500 hour maintenance in this section. SK210(LC)/SK250(LC)–VI Dynamic Acera OM, 09/00 Rev.2 4-37