MAINTENANCE B. CLIMATIZER-AC UNIT FILTER INSPECTION Inspect the fresh air filter every 250 hours of en- gine operation and the recirculate air filter every 500 hours of engine operation. SCREW SCREW SCREW REAR COVER NOTES • If the working environment is extremely dusty, it is rec- ommended to reduce the inspection schedule to at least half of the above specified working hours. • The fresh air filter is a paper filter. DO NOT WASH. Clean with air only. Do not clean more than 10 times, or replace it every 2 years. • Clean the recirculate air filter with compressed air or by washing and rinsing. • Do not wash recirculate air filter with any organic sol- vent, such as:
gasoline, trichlene, thinner, etc. LOCK LOCK REAR COVER SK32004088 FIGURE 4.39A Removing the climitizer-AC unit filters: 1. Fresh Air Filter a. Move the seat back forward for easy access to the rear panel. b. Release the 4 top screws from the rear panel top cover (behind the operator’s seat), see Figure 4.39A, and press the lower locks to release cover and remove it. Tilt the cover to- wards the seat to obtain access to the fresh filter. See Figure 4.39B. 4 SPEAKER WIRES NOTE To release the 4 top screws, turn them counter clockwise 1/4 of a turn (90є). FIGURE 4.39B c. Remove the fresh air filter for inspection and cleaning, or replacement. See Figure 4.39B. d.
After cleaning or replacement, use this pro- cedure in reverse for assembling. 2. Recirculate Air Filter a. Repeat above steps a, and b. b. Pull out the speaker wires and carefully re- move the top cover from the cab. c. Press the locks on the lower cover to release it and remove it to obtain access to the recir- culate air filter. See Figure 4.39A. d. Raise recirculate air filter slightly and pull it out for inspection and cleaning, or replace- ment. See Figure 4.39C. e. After cleaning or replacement, use this proce- dure in reverse for assembling. FIGURE 4.39C SK210(LC)/SK250(LC)–VI Dynamic Acera OM, 09/00 Rev.2 4-39