Kobelco — 2. SK250(LC)-VI and SK250NLC-VI 4-

MAINTENANCE 4.9 500 HOUR (6-MONTH) INSPECTION & MAINTE- NANCE PROCEDURES. WARNING WEAR GOGGLES, SAFETY SHOES, HARD HAT, WORK CLOTHES AND WORK GLOVES TO PERFORM INSPECTION AND MAINTE- NANCE ON THIS MACHINE. A. CHANGE OIL IN TRAVEL MOTOR REDUC- TION UNITS (SK210(LC)-VI, SK250(LC)-VI & SK250NLC-VI) Change the travel reduction units oil on a new machine after the first 500 hours of engine opera- tion then change every 2000 hours. 2. SK250(LC)-VI and SK250NLC-VI a. Move machine to a firm, level surface. Oper- ate travel until “FILL” plug is positioned at 12:00 o’clock, “LEVEL” plug at 3:00 o’clock, and “DRAIN” plug at 6:00 o’clock. See Fig- ure 4.41B.

WARNING NEVER CHANGE OILS OR FILTERS ON A MACHINE THAT HAS JUST FINISHED WORKING. ALLOW SUFFICIENT TIME FOR THE MACHINE TO COOL DOWN BEFORE PERFORMING ANY MAIN- TENANCE. 1. SK210(LC)-VI a. Move machine to a firm, level surface and place the attachments on the ground. Oper- ate travel until “DRAIN” plug is positioned at 6:00 o’clock. “FILL/LEVEL” plug should be on the top left side at about 10:00 o’clock. See Figure 4.41A. FILL PLUG LEVEL PLUG 4 DRAIN PLUG FIGURE 4.41B b. Stop engine and place an empty container under the drain plug. NOTE Capacity of each travel motor reduction unit is 4.7 liters (1.2 Gallons). FIGURE 4.41A b. Stop engine and place an empty container under the drain plug. c.

Remove “FILL”, “LEVEL”, and “DRAIN” plugs to drain oil into the container. d. After oil has been drained out completely, clean drain plug. Use teflon tape on drain plug for additional sealing and install it. Tighten securely. e. Add gear oil #90 grade GL-4 through the fill opening until oil starts flowing out of the level opening. f. Clean fill and level plugs. Use teflon tape on plugs for additional sealing and install them. Tighten both plugs securely. Capacity of each travel motor reduction unit is 5.5 liters (1.5 Gallons). NOTE c. Remove “FILL/LEVEL” and drain plugs to drain oil into the container. d. After oil has been drained out completely, clean drain plug.

Use teflon tape on drain plug for additional sealing and install plug. Tighten securely. e. Add gear oil #90 grade GL-4 through the FILL/LEVEL opening until oil starts flowing out. f. Clean FILL/LEVEL plug. Use teflon tape on plug for additional sealing and install it. Tighten securely. CAUTION Clean up all spilled oil. Dispose of all hazardous waste in accordance with government environmental regula- tions. SK210(LC)/SK250(LC)–VI Dynamic Acera OM, 09/00 Rev.2 4-41 FILL / LEVEL PLUG DRAIN PLUG