MAINTENANCE 4. Follow the procedure below and check the re- frigerant volume by looking thorough the sight glass (inspection window) on the upper part of the receiver dryer. See table below for better reference. 5. Make sure to change the position of the auto accel connector to activate the auto accel func- tion for normal machine operation. See Figure 4.43A (previous page) for better reference. E. FUEL SYSTEM INJECTION PRESSURE AND NOZZLE CONDITION (Atomization) Perform this inspection and adjustment every 500 hours of engine operation. Contact your Kobelco dealer’s Service Department for assistance. a. Figure A shows that the refrigerant volume is proper. b.
Figure B shows that the refrigerant is over charged. This will make both high and low pressure extreme and exert a bad influence on the pressure switch operation and the air conditioning system. Initial injection pressure: 220 kgf/cm 2 (3129 psi) c. Figure C shows that the refrigerant is insuf- ficient. Have the refrigerant recharged at your KOBELCO distributor. 4.10 1000 HOUR (12-MONTH) INSPECTION & MAINTENANCE PROCEDURES. 4 A. ENGINE VALVE CLEARANCE Check and adjust the engine valve clearance ev- ery 1000 hours of engine operation. Contact your Kobelco dealer’s Service Department for assis- tance. Adjust exhaust and intake valves at 0.4 mm (0.016”) (With cold engine) B.
ENGINE COMPRESSION PRESSURE SK210(LC)/SK250(LC)–VI Check Engine Compression every 1000 hours of engine operation. Contact your Kobelco dealer’s Service Department for assistance. NOTE New refrigerant (HFC-134a), whose characteristics are different from conventional CFC-12, is used in this machine. Do not mix HFC-134a with CFC-12. Operate the air conditioner at least once every week for several minutes to rotate the compressor regard- less of the season. This will prevent the refrigerant gas from leaking from the compressor sealing. Compression pressure: 26 Kgf/cm 2 (370 psi) @ 200 rpm at engine temperature between 75~85 єC (167~185 єF) C.
INSPECTION OF STARTER AND ALTERNATOR Check Starter and Alternator every 1000 hours of engine operation. Contact your Kobelco dealer’s Service Department for assistance. It is neces- sary to disassemble these components for proper cleaning and inspection. Bubbles: Refrigerant gas is mixed with refrig- erant fluid. D. ENGINE FUEL INJECTION TIMING Check Engine Fuel Injection timing every 1000 hours of engine operation. Contact your Kobelco dealer’s Service Departement for assistance. No Bubbles: Whole refrigerant becomes fluid and transparent. Injection timing: SK210(LC)–VI 15є BTDC SK250(LC)–VI 17є BTDC Cloudy: Refrigerant is separated from oil. The fluid becomes a light milky white.
4-44 SK210(LC)/SK250(LC)–VI Dynamic Acera OM, 09/00 Rev.2 Refrigerant volume Description A Proper After the air conditioner is turned ON, little bubbles appear. The refrigerant becomes transparent, then turns a light milky white. B Overcharged After the air conditioner is turned ON, no bubbles appear. C Insufficient After the air conditioner is turned ON, bubbles appear continuously.