MAINTENANCE 4.11 2000 HOUR INSPECTION & MAINTENANCE PROCEDURES Perform all other Inspection & Maintenance Proce- dures as previously described in this section. A. ENGINE COOLANT CHANGE WARNING BE CAUTIOUS OF HOT FLUIDS AND SURFACES. WEAR GOGGLES, SAFETY SHOES, HARD HAT, WORK CLOTHES AND WORK GLOVES TO PERFORM INSPECTION AND MAINTENANCE ON THIS MACHINE. ALLOW SUFFICIENT TIME FOR THE ENGINE TO COOL BEFORE CHANGING FLUIDS. 1. Move the machine to a firm level area, place the attachement on the ground and shut off the engine, see Fig. 4.45A. 4 SK32001028 FIGURE 4.45A 2.
Locate the one pin connector for the auto- acceleration function behind the operator’s right hand console and change the position of the connector as indicated in Figure 4.45B. 3. Raise the engine cover, secure it open, and place a rag or paper towel on the radiator cap. Slowly remove the cap. The system could be under pressure. See Figure 4.45C FIGURE 4.45C 4. Locate the lower cover beneath the radiator. See Figure 4.45D. Remove bolts and cover to obtain access to the radiator drain hose. Place an empty container, with sufficient ca- pacity for engine system coolant, below the radiator drain hose. Refer to page 4-10 for proper system capacity. Turn valve counter clock wise to open drain.
CAUTION Clean up all spilled coolant. Dispose of all hazardous waste in accordance with government environmental regulations. FIGURE 4.45D SK210(LC)/SK250(LC)–VI Dynamic Acera OM, 09/00 Rev.2 4-45 Normal position. Auto-accel. ON Maintenance position (Auto- accel disconnected) Maintenance pos accel disconnected Maintenance pos accel disconnected FIGURE 4.45B LOCK COVER OPEN REMOVE RADIATOR CAP