Deutz — 5.2.2 ALARMS INDICATED ON THE TRANSMISSION DISPLAY AND BY THE EDS PROGRAM

5.

ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS 20-80 Alarm code Alarm description Operating mode Page 16 The control unit detects a short circuit to earth on the control line of the Infocenter light indicating low transmission oil pressure 20-89 17 The control unit detects a short circuit to positive on the control line of the Infocenter light indicating low transmission oil pressure 20-90 18 The control unit detects a discrepancy between the oil pressure reading and the operating status of the transmission 20-91 19 The control unit detects the transmission display control signal short-circuiting to earth 20-92 20 The control unit detects the transmission display control signal short-circuiting to positive 20-93 21 The control unit detects a ground speed higher than the permissible limit 20-94 22 The control unit detects a transmission oil temperature higher than the permissible limit with the machine operating in “FIELD” mode 20-94 23 The control unit detects a transmission oil temperature higher than the permissible limit with the machine operating in “ROAD” mode.

20-94 24 The control unit detects the main clutch running overspeed. 20-95 36 The control unit detects that solenoid Y4 is either not connected or faulty. Stand-by strategy 20-96 37 The control unit detects that the control line of solenoid Y4 is short- circuiting to earth Stand-by strategy 20-97 38 The control unit detects that the control line of solenoid Y4 is short- circuiting to positive Stand-by strategy 20-98 39 The control unit detects that solenoid Y2 is either not connected or faulty.

Stand-by strategy 20-99 40 The control unit detects that the control line of solenoid Y1 is short-circuiting to earth Stand-by strategy 20-100 41 The control unit detects that the control line of solenoid Y1 is short-circuiting to positive Stand-by strategy 20-101 47 The control unit detects that the rpm sensor nAb is disconnected or short-circuiting to positive Limp-Home 20-102 48 The control unit detects that the rpm sensor nAb is short-circuiting to earth Limp-Home 20-103 49 The control unit detects unreliable information coming from the rpm sensor nAb Limp-Home 20-104 50 The control unit detects that the rpm sensor nHk is disconnected or short-circuiting to positive Limp-Home 20-105 51 The control unit detects that the rpm sensor nHk is short-circuiting to earth Limp-Home 20-106 52 The control unit detects unreliable information coming from the rpm sensor nHk Limp-Home 20-107