5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM N° 90 DESCRIPTION The control unit detects an abnormal level of current drawn by the powershift solenoid valves Y2, Y4. ECU RESPONSE The control unit limits operation to “TC-SHUTDOWN” mode and the transmission reverts to neutral, emitting a continuous beep. NOTE This alarm could be displayed as a result of alarms 38 and 41 being activated. CHECK With the starter key in the “O” (OFF) position and connector “ECU PS” unplugged, connect a test meter to pin F of con- nector “EV GROUP”, and measure the resistance to verify whether or not there are short circuits to earth (meter reading: infinity).
With the starter key in the “I” (ON) position and connector “ECU PS” unplugged, connect a test meter to pin 8 of con- nector “EV GROUP” and check that there is no voltage registering (meter reading: 0V). With the starter key in the “I” (ON) position, check that the power input to the solenoid valves is correct (12V measured between pin F (positive) of connector “EV GROUP” and transmission earth) With the starter key in the “I” (ON) position, connect a test meter to pins 23 and 68 and measure the voltage (meter read- ing:
12V) Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 20-129 0.012.8732.4 1 2 8 32 11 13 21 23 45 55 57 68 2145 23 68 1 2 11 8 57 32 13 55 ECU PS GND4 J2 TKAB1 3 6 F35 F27 7.5A 7.5A +15 +30 0441.9533 5 1 6 17 21 16 E F C D A B EV GROUP Y4 Y2 Y3 Y1 0.012.8672.4 D0017281 21 45 23 68 1 2 11 8 57 32 13 5 GND4 J2 3 6 17 21 1 C D A B