Deutz — 5.2.4 ANALYSIS OF ALARMS

5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM GEN2 DESCRIPTION Transmission slips unexpectedly from forward or reverse drive into neutral. ECU RESPONSE The display indicates forward drive, reverse drive and neutral status simultaneously, and a continuous beep is sounded. CHECK Reprogram the control unit, entering the correct tractor model data, and repeat the calibration procedure for the main clutch and the clutch pedal. Check the wiring, following the procedures described for alarms 53, 54, 55, 56, 57 and 58. Check the pressure in the hydraulic circuit of the transmission system.

Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. ALARM GEN3 DESCRIPTION The transmission continues to shift range automatically every 1 or 2 seconds ECU RESPONSE None CHECK Reprogram the control unit, entering the correct tractor model data, and repeat the calibration procedure for the main clutch and the clutch pedal. Check the wiring, following the procedures described for alarms 36, 37, 38, 39, 40 and 41. Check the wiring, following the procedures described for alarms 53, 54, 55, 56, 57 and 58. Check the pressure in the hydraulic circuit of the transmission system.

Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 20-137