EDS (Electronic Diagnosis System) DIAGNOSIS OF THE INFOCENTER Fig. 57 - Set outputs The last line “End output menu” is marked by a bar. Press the cursor keys to move the bar to the desired function and start the function by pressing ENTER. Set outputs > Lamp test All LEDs (light emitting diodes) in the INFOCENTER are tested. - Indication: All LEDs are lighting up. For terminating the test step select “Reset outputs” and press the RETURN key. - Indication: All LEDs are extinguishing. Set outputs > Warning lamp The central warning light in the INFOCENTER 3 is tested. - Indication: The warning light is lighting up. For terminating the test step select “Reset outputs” and press the RETURN key.
- Indication: The warning light is extinguishing. Set outputs > Beep The acoustic alarm - beep - in the INFOCENTER 3 is tested. - Indication: The acoustic alarm - beep – is sounding. For terminating the test step select “Reset outputs” and press the RETURN key. - Indication: Beep stops. Set outputs > true ground speed With this test step a signal is transmitted from the output of the true ground speed (plug X130 pin 5) to pin 1 of the signal socket. - Indication: Ground frequency on. Now a voltage signal is existing at the 7-pole signal socket. Measuring is possible between pin 1 (true ground speed sig- nal) and pin 7 (ground). - Setpoints with ground frequency on: approx.
0,8 V (DC) with ground frequency off: approx. 8 V (DC) 20-227