Deutz — 4.1 PROGRAM DESCRIPTION

EDS (Electronic Diagnosis System) DIAGNOSIS OF THE INFOCENTER Set outputs > theor. ground speed With this test step a signal is transmitted from the output of the theoretical ground speed (plug X130 pin 11) to pin 2 of the signal socket. - Indication: Wheel frequency ON. Now a voltage signal is existing at the 7-pole signal socket. Measuring is possible between pin 2 (theoretical ground speed signal) and pin 7 (ground). - Setpoints:with wheel frequency on: approx. 0,8 V (DC) with wheel frequency off: approx. 8 V (DC) Set outputs > rear P.T.O. With this test step a signal is transmitted from the output of the power take-off speed (plug X130 pin 6) to pin 3 of the sig- nal socket.

- Indication: RPTO frequency on. Now a voltage signal is existing at the 7-pole signal socket. Measuring is possible between pin 3 (power take-off speed signal) and pin 7 (ground). - Setpoints: with RPTO frequency on: approx. 0,8 V (DC) with RPTO frequency off: approx. 8 V (DC) Set outputs > Reset outputs All set outputs are reset and replaced by the original values. Select “End output menu” and press the ENTER key to reset all outputs automatically and change into the test mode. TEST MODE > F3 CHECK LCD Upon pressing the key F3 the following window appears: Fig. 58 - Check LCD displays The last line “End LCD menu” is marked by a bar.

Press the cursor keys to move the bar to the desired function and start the function by pressing ENTER. 20-228