SERDIA SETUP AND COMMUNICATIONS 1.3.5 SETTING UP THE LINK BETWEEN CONTROL MODULE (ENGINE) AND NOTEBOOK Communication characteristics: Serial communication BaudRate = 9600 Serialport = COM1 The SERDIA interface (supplied) is used to connect the control module to a Notebook. Despite the numerous safety pre- cautions in the interface and control module (such as protection against wrong pole connection and overvoltage, and gal- vanic isolation), mistakes can still happen, and the following procedure should always be applied when connecting the Notebook to the control module. The connection is set up in the following order: 1) Switch off the engine, ignition switch (Circuit 15) is Off.
Do not switch on the Notebook yet. 2) Connect the diagnostic connector to the vehicle / installation diagnostic socket. The diagnostic connector must be provided by the customer, and can be supplied by DEUTZ on request. 3) Connect the other side (interface side) to the RS 232/COM1 serial interface. (9-pin connector on the back of your Notebook). Note: On PCs, the COM1 interface may already be occupied by the mouse. In this case, the interface must be connected to the PC's serial interface (COM2). This must then be configured (see Chapter, "What to do if ...). 4) The ignition switch (Ct.15) and Notebook can now be switched on. The engine remains off at first.
5) The SERDIA can now be started as describe in Chapter 1.8, "Starting the Program". 1.3.6 STARTING THE PROGRAM In the Windows environment, the SERDIA program is started by clicking twice on its icon. Starting for the first time: When the program is started forthe first time, the control module is interrogated. SERDIA does this to find out which control modules are connected and can therefore be addressed. This process can last for about 30 seconds, as the program in- terrogates all the possible control modules one after the other. While this is taking place, the message "Startup routine for connected ECUs“ is displayed.
The "ECU selection“ subscreen then appears, in which unidentified control units are greyed out. Select the desired control unit and click OK. The message "Initialisation is active!“ appears (and remains for about 7 seconds). Communications are then set up with the control unit. 20-261