Deutz — 1.4 USING THE PROGRAM

SERDIA SETUP AND COMMUNICATIONS 1.4.2 "ECU SELECTION“ MENU DEUTZ engines may be equipped with one or more control units (for example, an MVS/ EMS2 combination). However, SERDIA can only communicate with one control unit. Exception: error lists and measured values can also be read from the MVS control unit through an EMS2. The desired control unit must therefore be selected first in the "ECU selection“ menu. For more details, see Chapter 2, "ECU selection". 1.4.3 MEASURED VALUES" ("ACTUAL MEASURED VALUES“) MENU A number of measured values (including inputs/outputs) can be selected from a list of values and displayed.

Displayed values falling outside the maximum or minimum limit (if present) are shown on a coloured background. Only measuring points that match the control unit are shown, with different display options: Read measured values Read measurement electronics Read logger data (special EMS2 menu) arranged by designation value unit Measured values are refreshed at a pre-set scan rate and can be displayed both with engine stopped and with engine run- ning. For more details, see Chapter, "Measured values". 1.4.4 "PARAMETERS" MENU The wide-ranging possibilities of DEUTZ control units require special programming to adapt them to their particular en- vironment.

Changes to parameters are necessary when access is required, due to customer request to adapt to local conditions to fit a replacement. Parameters can only be changed through SERDIA! This menu option can be used to replace the screwdriver setting (necessary with analog control units). Some of the parameters (for example, dynamic control response) can be modified within certain pre-set limits. Parameters are set through two screens, one for configuration and one for calibration. Access to the fields in the related screens depends on user authorisation. Unauthorised fields are not shown. For more details, see Chapter 4, "Parameters".

1.4.5 "ERROR MEMORY" MENU This menu is used to read any error messages stored in the control units. Error messages are related exclusively to electrical parts of the engine, such as cable harness and transducer. For example, one error message could be "General fault or cable cut/short-circuit“. Only passive error messages can be deleted; active messages are saved. Active error messages become passive messages when they have been cleared. Error messages are saved even when the battery/voltage supply is disconnected. Error messages contain the following information:

Fault location Fault type Environmental data at time of fault Total error count (per fault location) Frequency Emergency mode (yes / no) For fault clearing, the user can refer to the SERDIA Help screens; it may also be helpful to refer to the "Measured values“ and "Function test“ menus. For more details, see Chapter 5, "Error memory". 20-265