SERDIA SETUP AND COMMUNICATIONS 1.4.6 "FUNCTION TEST" MENU SERDIA supports wide-ranging function tests, differentiating between the control units installed (for example, testing the actuator for the EMR1). The function test option also provides valuable help, especially for troubleshooting and maintenance work. Individual control unit outputs can be activated and checked separately. This is done by switching to Test mode. The engine must be switched off first! In the Function test, the control unit transmission program is bypassed and actuators are controlled by the test program.
Actuators are switched on and off by clicking on the little control box in the Actual Value column, beside the actuator's des- ignation reference. "Actual Value" shows the response for the actuator status set by the control unit. The actuator status test always takes place in the control unit, and can only be transferred to the SERDIA by the control unit itself. This means that if the desired actual value does not appear, there may be a wiring fault. The "Error memory“ and "Function test“ menu combination can be of help in determining the source of a fault.
Indirect indications about engine condition can also be obtained using the "Function test" menu in combination with the MVS control unit. For more details about the function test, see Chapter, "Function test". 1.4.7 "EXTRAS" MENU SERDIA supports wide-ranging options specific to the control unit. These are accessed through the related submenus, which have their own screens: Maximum speed Logistic data Load spectrum (EMR2 and EMS2) Maintenance interval exceeded Override memory Maintenance data For more details, see Chapter, "Extras". 1.4.8 HELP The SERDIA Help function can be used in conjunction with these user instructions.
In Windows, the Help function is opened by clicking on the "Help“ button. 1.5 CLOSING THE PROGRAM Before disconnecting the cables between the Notebook and the engine control unit, go back to the main screen and click on the "Close“ button. If parameters have been changed, in many cases it is worthwhile checking the current parameter settings. To do this, follow the steps below: 1. Close SERDIA 2. Switch off the engine supply voltage, then switch on again 3. Re-start SERDIA 4. Activate the control unit again 5. Open the "Parameters“ menu 6. In the configuration screen, click on the "ECU->PC“ button 7. Print out the configuration data by clicking on the "Print“ button 8.
Keep the printed data with the engine documentation. 20-266