SERDIA MEASURED VALUES 3. MEASURED VALUES 3.1 ACTUAL MEASURED VALUES (GENERAL) The measured values are read out cyclically and displayed on the "Actual measured values" screen. Values outside the sensor's measuring range have coloured backgrounds: Yellow: Measuring range is exceeded, Blue: Below measuring range. EXPLANATION OF THE FUNCTION BUTTONS: Meas. values : The "Measured value selection" window containing all the available measured values is displayed. The measured values that are to be displayed can be selected from here. In general, the repeat rate of the display is in- creased if there are not many measured values to be displayed.
The number of available measured values varies, de- pending on the type of control unit. Graphics : The button "Graphics" displays, in the form of a graphic, the progress over time of the selected measured values (maximum of 5). If more than 5 measured values are selected, an error message will appear. Collect. time : The recording period is displayed in the Measurement duration field in seconds. The minimum value for the recording period is one second. A few hours (expressed in seconds) can be entered for the upper measuring time. The default setting is 10 s. The shortest scanning rate is 40 ms for RAM values and 60 ms for other values.
For a measuring period of 10s, therefore, the total number of measuring points for RAM values is: 10000 ms/40 ms = 250 and for other values: 10000 ms/60 ms = 166. Since the program records an approximate maximum of 2000 measuring points, the scanning rate is automatically ad- justed - accordingly before the beginning of the data recording phase. The minimum possible scanning rate is determined by the duration of data transmission from the control unit to the PC. The more measured values that are to be displayed simultaneously, the longer the data transmission period and there- fore the lower the scanning rate will be. File :
The current measured values can be stored in a file and reloaded at a later date, for example for further processing in Excel. Print : The displayed measured values are printed out. Close : Return to the main window "Service diagnosis". 20-271