SERDIA EMR2 ERROR TABLE 20-293 Emergency stop Check engine (oil level, oil pump). Check oil pressure sensor and cable. Check oil pressure switch-off limit. Check coolant level. Check coolant level sensor and cable. Check switch-off limit. Check charge air. Check charge airtemperature sensor and cable. Check switch-off limit. Check coolant level. Check coolant level sensor and cable. Check actuator, replace if required. Check cable, check “Confirmation”. Check actuator, replace if required. Check cable, check fault limits for “Rifeness confirmation”. Check actuator/ actuator rods / injection pump, replace if required Check actuator cable. Check actuator and replaced if required.
Check feedback cable. Check voltage supply/cables. Check fault limits and reference values of the feedback. Program the fault limits for feedback, save values. Switch ignition off and on again. Check again.«If faulty, inform DEUTZ-Service and carry out automatic equalization again. Set fault limits again. Emergency stop. Emergency stop. Start lock. Emergency switchoff. Actuator cannot be operated. Fault message (disappears when difference is Engine stop / start lock. Governor cannot be taken into use. EDC actuator calibration required (see Chapter 8.4). Oil pressure below switch-off limit Coolant temperature has exceeded switch-off limit. Charge air temperature has exceeded switch-off limit.
Switch input “Low coolant level is active. Actuator not connected. Fault in actuator confirmation. Injection pump/actuator jammed or not connected. Difference between nominal/actual control travel is > 10 % of the overall control path. No automatic actuator equalization possible. Incorrect input of the actuator reference values. 1 2 3 5 1 2 3 3 3 3 5 5 2 2 2 2 2 2 Oil pressure switch off Coolant temperature switch-off Charge air tempera- ture switch-off Coolant level switch off Feedback Reference feedback Control travel difference Auto calibration BOSCH-EDC pumps faulty operation 40 41 42 44 50 52 53 59 Functional fault, switch-off Actuator