Deutz — 8.2 EMR1

SERDIA WHAT TO DO IF...? Governor basic setting: The control unit is programmed at the end of the band with the following standard values. Standard values may vary according to engine model and application Standard values, speed and load dependent parameters: 3 performance maps for the P, I, and D part = fkt (speed, quantity injected).. Making a setting correction: Before modifying any parameters, we recommend saving the current configuration using the "Save in file" menu option, and/or printing configuration pages 4, 5 and 17. The setting procedure consists of 3 stages: 1. PID governor basic parameters For the most part, the correction is made with the basic parameters.

If a new governor basic setting is required, set all performance maps (Page 17) to 100%. The P part is the most important parameter and must be set first. Raise the parameter value for "SpeedGvnr: P part" by 10 % to begin with, until the engine accelerates under the the sudden load variation and vibration dips to f > 1 Hz. Then reduce the P part again by 25 %. Example: P part with vibration dip (unstable) = 12. 12-25 % of 12 = 9 (new setting value). The setting depends heavily on weight moment of inertia (engine + generator). For weight moments of inertia up to 8kgm2 the value range for the P part is between 10 and 45 %. At higher moments of inertia, the P part can be raised by up to 90 %.

Note regarding major engine assemblies:The optimum governor values are determined at operating speed with dif- ferent loads. Note the P part determined for each, and enter the average in "SpeedGvnr: P part". For double-frequency installations, the second frequency must be included in the average value calculation. Note regarding vehicle engines:The optimum governor values are determined at several engine speed and load points. 20-306 Parameter (Variable) Standard value Comment Assembly Vehicle SpeedGvnr: P part 18-20 4,0 Basic setting gain factors for P/I/D parts. These parameters are independent of engine status (speed, load still active) and show the main instruments for governor setting.

SpeedGvnr: I part 10,0 10,0 SpeedGvnr: D part 5-12 2,5 SpeedGvnr: damping 90,0 65,0 Lowering the governor parameter for the static range. SpeedGvnr: damping range 15,0 80,0 Speed band around nominal value. Within this speed band, the engine runs smoothly and with precision, and does not respond strongly to speed variations. PosGvnr: P part 10,0 10,0 Setting corrections should only be made after con- firming PosGvnr: I part 10-15 5,0 PosGvnr: D part 5-10 5,0 PosGvnr: DT2 part 8,0 8,0 SpeedGvnr: damping 160-180 180,0 SpeedGvnr: damping 0,25 0,25 Parameter (Variable) Standard value Comment X: Engine speed position values (r.p.m.) 60…2500 7 speed values Y:

Quantity position values (cmm/str) 0, 20 …100 4 injection quantity values Map (%) 100 Total 3 x 28 entries. A 100 % entry causes the speed gov- ernor PID parts to be accepted (Page 4). Corrections must be made at the related measurement point. EMR1