SERDIA WHAT TO DO IF...? Parameter designations Measuring the limit values: Open the "Measured values" menu, "Actual measured values". Measured value "(F24)Accelerator pedal=SWG1“: with pedal in parked position (lower reference) and pedal pressed (lower reference), "Get value", transfer to the control unit and save. Configuration: Open the "Parameters“ menu, "Configuration" option. Enter values, referring to the following example table ("Acc. pedal input configuration", see below). Conversion: 5 V=1023 digits. Example: Acc. pedal input configuration 1) Measured value "upper reference point" + 5 % (v.
upper reference point) 2) Measured value "lower reference point" -5 % (v.lower reference point) 8.2.3 MANUAL THROTTLE CALIBRATION The manual throttle (Pin 20 FS) is intended for vehicles such as agricultural machines. When ploughing, for example, a driv- er can make the appropriate engine speed setting and then take his/her foot off the accelerator pedal. As with the me- chanical adjusting levers, the manual throttle position must be set to zero (lowest engine speed) before starting the engine. The manual throttle positioning is combined with the accelerator pedal and determines minimum speed.
In proportion to the preset nominal value, engine speed can be set between lower idle speed (for example 650 r.p.m.) and nominal engine speed (for example 2300 r.p.m.). Depending on the manual throttle setting, the engine responds in the same way as to an accelerator pedal. For example, if the speed is set with the hand throttle to 1500 r.p.m., accelerator pedal operation only becomes effective at higher speeds than this. Manual throttle positioning is not supplied by DEUTZ, but it still has to be programmed at the factory. A potentiometer can be used as the adjusting link, and installed by the customer.
Requirements for manual throttle nominal value setting (potentiometer) when installed by customer: Input Pin 20 vehicle connector Potentiometer supply as pedal value sensor, 5V reference voltage Pin 25, and GND Pin 23. Loading reference voltage together with pedal value sensor Protection system IP65 End stops adjusted to between 10 % and 90 % of the potentiometer value. For example, if potentiometer resistance = 1 k., the setting range between mechanical stops must then be between 100 Ω and 900 Ω . This setting range can be achieved by a) Narrowing the turning angle 20-308 Configuration screen Calibration screen Value AccPedal(SWG1)up. err val.
Acceler(SWG1)upper fault limit [full throttle...5V] max. setpoint x 1.05+ AccPedal(SWG1)up. ref Acceler(SWG1)full throttle [pressed down, upper limit] max. setpoint AccPedal(SWG1)lo. ref Acceler(SWG1)parked position [lower limit] Pedal at rest = Idle AccPedal(SWG1)lo. err val. Acceler(SWG1)lower fault limit [0V...parked pos.] Pedal at rest - 0.05 x max. setpoint Parameter Factory setting Actual value/ measured value Calibration Configuration mV digits mV mV digits AccPedal(SWG1)up.err val. 4750 973 4357 1 893 AccPedal(SWG1)up. ref 4500 921 4150 4150 850 AccPedal(SWG1)lo. ref 500 102 670 670 137 AccPedal(SWG1)lo. err val. 250 51 463 2 95