SERDIA WHAT TO DO IF...? 8.2.6 ENGINE STOPS FOR NO KNOWN REASON 8.2.7 REPLACING THE EMR1 ACTUATOR The actuator is a purely mechanical component of the EMR1, fixed to the engine. It contains a solenoid controlled by the EMR1, which positions the control rod and thus regulates the fuel feed to the engine. A fuel rack position sensor fitted into the actuator indicates the control rod position to the EMR1. The following error messages may make it necessary to replace the actuator: 8113:(M17)Rack travel sensor 8405:Actuator (positioner, travel meter, fuel rack) Replacement instruction: Switch off the voltage supply to the EMR1 and detach the connection cable from the actuator.
For safety reasons, the positive terminal of the battery must be disconnected. Remove the actuator and clean the mounting surface on the engine. IMPORTANT: With the actuator removed, the control rod is at maximum filling position, i.e. the engine must not be started in any circumstances! Attach the new actuator with sealant (DEUTZ Part No. 0101 6102) to the engine. When fitting a new actuator, check that it is compatible with the control unit. At the moment, there are 3 possible combinations for replacement: 20-311 Indication Possible cause Remedy Following shutdown: (Key switch not yet actuated, off/on) Error pilot light off ! Shutdown not initiated by error message in the EMR.
Other possibilities: Fuel supply ! Speed monitoring independent of EMR. Interruption of supply voltage. Restore fuel system. Check whether additional speed monitoring (e.g. solenoid) is available and make relevant system check. Check EMR vehicle connector, fuse, key switch etc. for loose contact. Following shutdown: (Key switch not yet actuated, off/on) Error pilot light Permanent light Trace error location and error environment with SERDIA. Error message: Overspeed (is reached for instance upon sudden load change) !e.g. ”Oil pressure” additonal remark: “inactive”. Carry out systematic check depending on er- ror message: Guide value: rated speed+15% to be correct- ed if necessary.
Check connector on oil pressure sensor for loose contact and replace sensor if neces- sary. Following shutdown: (Key switch not yet actuated, off/on) Error pilot light flashing There is a serious error in the EMR system. Prior to engine start, trace error location with SERDIA. Take action according to the indicated error location. This may involve replacing the ECU, actuator or sensor. The additional remark “in- active” indicates a loose contact at the indi- cated error location.