Deutz — 8.2 EMR1

SERDIA WHAT TO DO IF...? METHOD 1. 1. Step: Read engine data set from old control unit: Switch on ignition/supply voltage. Open the SERDIA program. In SERDIA, select the "Parameters“ menu ->"Overall programming". Click on the "ECU -> file" button. The configuration data files are read. The "Save as " window then opens. Give the file a name, and save. When saving, the engine number is prompted as the file name - this is only a suggestion. Any other name can be entered. Finally, click OK to confirm. The file (i.e. the engine data set) is then saved under the name .hex.

The data transferred from the old control unit includes, among other things, indications of the number of operating hours and number of engine starts. Close the program. Switch off the ignition/supply voltage. 2. Step: Replacing the control unit: Control unit compatibility must be considered, and checked against the above table (Part Numbers should be the same.). Compatibility of the control unit with the actuator must also be checked and verified. Switch on ignition/supply voltage. Open the SERDIA program. In SERDIA, select the "Parameters“ menu ->"Overall programming". Click on the "Programming" button. The "Open" window is displayed.

Select the saved engine data set ( .hex) by double-clicking on it. Transfer the engine data set to the EMR1 by clicking on the "OK" button. Save the data set in the control unit by clicking on the "Save in ECU" button. 3. Step: Start the engine and check that it runs satisfactorily. In the "Error memory" menu clear the error memory. 20-314