Doosan DX225LC-3 — Hydraulic System Warm-up

When making the last connection to upper frame, be sure to connect the cable end as far away from the machine batteries as possible. DO NOT CONNECT DIRECTLY TO THE NEGATIVE BATTERY TERMINAL. 4. Start the engine. Disconnecting Booster Batteries 1. Disconnect black negative (-) cable (2, Figure 15) from the machine frame (5) first. 2. Disconnect the other end of black negative (-) cable (2, Figure 15) from the booster batteries (3). 3. Disconnect red positive (+) cable (1, Figure 15) from the booster batteries (3). 4. Disconnect red positive (+) cable (1, Figure 15) from the machine batteries (4).

Hydraulic System Warm-up IMPORTANT If a problem or abnormal operation occurs, immediately stop engine. Allow excavator to reach normal operating temperature before starting work, especially in cold weather. The correct operating temperature of the hydraulic oil is 50° - 80°C (120° - 175°F). Make sure to follow the procedures listed here for hydraulic fluid warm-up. 1. Run engine for approximately five (5) minutes set at the middle of the speed range, without a load. FG018151 Figure 16 DX225LC-3 Operation 3-12