Doosan DX225LC-3 — Releasing the Work Tool

Releasing the Work Tool 1. Place the excavator and quick coupler on the level ground. 2. Set quick coupler switch to "I" (UNLOCK) position. NOTE: To remove holding pin, maintain hydraulic relief condition for 2 - 3 seconds in bucket crowd position, with the switch turned on. O I NOTE: Whenever the hitch part is extended, a warning alarm will sound. When setting switch to "O" (LOCK) position, the warning alarm will stop. FG019092 Figure 136 3. Retract the bucket cylinder to move the quick coupler toward the machine. FG019093 Figure 137 4. Set quick coupler switch to "O" (LOCK) position. Lower and move the arm away from the work tool and toward the machine.

O I FG019094 Figure 138 DX225LC-3 Operation 3-66